MORETTI MONITOR DE PACIENTE MULTIPARÁMETROS - DISPLAY 12,1" (LTD345) View larger

MORETTI MULTIPARAMETRO PATIENT MONITOR - DISPLAY 12.1" (LTD345)

Product ID: 4032

High resolution LCD-TFT large patient monitor.

More details

1 859,99 €

+ wishlist

GENERAL CHARACTERISTICS

  • Rugged and compact structure.
  • Large high resolution LCD-TFT color screen
  • Handle for easy movement.
  • Display of ECG, RESP, SpO2, NIBP, PR, 2-TEMP
  • Suitable for adult and neonatal use. Arrhythmia analysis. Pacemaker, defibrillation and protection against electrosurgical interference
  • 96 hours of memory of all values, 500 NIBP measurements and 60 alarm events. USB port
  • Optional integrated printer.

EQUIPPED WITH -

  • 1 5-way ECG cable with anti-defibrillation clip, IEC, 3.5m, reusable
  • 30 ECG Electrodes, adult, disposable
  • 1 SPO2 finger sensor, adult, 2.5m, reusable
  • 1 NIBP Wristband, Adult, 25cm-35cm, reusable
  • 1 NIBP tube, 3m
  • 1 Probe Skin temperature probe, adult, 3m, reusable
  • 1 power supply (EUR standard)
  • 1 rechargeable lithium battery (14.8V, 2100mAh)
  • 1 ground cable



TECHNICAL FEATURES -

DISPLAY
TFT color LCD: 12.1 "
Resolution: 800x600
Displayed tracks: up to 8
Displayed waveforms: up to 11
Oscillation: 6.25, 12.5, 25, 50 mm / s
ECG
Derivatives: 5 Derivatives and 3 selectable derivatives
Display sensitivity: Auto x 0.125, x 0.25, x 0.5, x 1, x 2, x 4
Scan rate: 6.25, 12.5, 25, 50 mm / s
Heart rate (HR) range:
Adults 15 ~ 300 bpm
Pediatric / neonatal 15 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1 bpm or 1%
Filter: Diagnostic mode 0.05 - 150 Hz / Monitoring mode 0.5 - 40 Hz / Surgical mode 1 - 20 Hz
Diagnostic mode 0.05 ~ 150 Hz
Monitoring mode 0.5 ~ 40 Hz
Surgical mode 1 ~ 20 Hz
Segment tracking: Measuring range -2.0 mV ~ 2.0 mV / Alarm range -2.0 mV ~ 2.0 mV

RESP
Method: transthoracic impedance
Operation: automatic / manual
RR Measurement range:
Adults 0 ~ 150 rpm
Pediatric / Neonatal 0 ~ 150 bpm
Resolution: 1 rpm
Apnea alarm threshold:
10, 15, 20, 25, 30, 35, 40 s
Bandwidth: 0.2 - 2.5 Hz (-3 dB)
Scan rate: 6.25, 12.5, 25, 50 mm / s

SpO2
Measurement range and alarm: 0 ~ 100%
Resolution: 1%
Accuracy:
± 2% (70 ~ 100%, Adult, Pediatric)
± 3% (70 ~ 100%, Neonatal)
Pulse measurement: 25 ~ 300 bpm
Resolution: 1 bpm
Update rate: 1 second

NIBP
Method: Automatic Oscillometric
Operation: Manual / Automatic / Continuous
Measurement range in automatic mode:
1, 2, 3, 4, 4, 5, 10, 15, 15, 30, 60, 60, 90, 120, 240, 480 minutes
Unit of measurement: mmHg / kPa
Type of measurement: Systolic, Diastolic, Media
Pressure range:
- Adult
Systemic 40 ~ 270 mmHg
Diastolic 10 ~ 215 mmHg
Media 20 ~ 235 mmHg
Pediatric
Systemic 40 ~ 200 mmHg
Diastolic 10 ~ 150 mmHg
Media 20 ~ 165 mmHg
Neonatal
Systemic 40 ~ 135 mmHg
Diastolic 10 ~ 100 mmHg
Media 20 ~ 110 mmHg
Resolution: 1 mmHg
Accuracy: mean ± 5 mmHg error
Maximum standard deviation: 8 mmHg
NIBP Pulse measurement range: 40 ~ 240 bpm
Resolution: 1 bpm
Accuracy: 3 bpm or 3.5%

IBP (2 channels) available on models LTD346 - 348
Pressure measurement:
ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement range: 50 ~ 300 mmHg
Resolution: 1 mmHg
Accuracy: ± 2% or ± 1 mmHg
Sensitivity: 5μV / V / mmHg
Impedance range: 300 ~ 3000Ω

CO2 available on models LTD346 - 348
Type: Sidestream / Mainstream
Range: 0 ~ 150 mmHg
Accuracy:
± 2 mmHg 0 ~ 40 mmHg
± 5% 41 ~ 70 mmHg
± 8% 71 ~ 100 mmHg
± 8% 101 ~ 150 mmHg
AWRR Accuracy: ± 1 rpm

Temperature (2 channels, 1 probe supplied)
Measurement range / alarm range: 0 ~ 50 ° C
Resolution: 0.1 ° C
Accuracy: ± 0.1 ° C (without probe)
Channel: 2
Printer (Optional)
Print speed: 25, 50 mm / s

Power supply
Power supply: 100 ~ 240 V AC, 50/60 Hz
Rechargeable lithium battery: 14.8 V

Dimensions L: 32 x D: 15 x H: 26.5 cm
Weight 5 kg